High quality intramedullary nails designed for easy insertion and removal. Made from Titanium Alloy, these nails reduce the risk of outer wall impact and main nail inward movement. The diameter is suitable for all applications, featuring simple operation and minimally invasive implantation.
| Product Name | Model | Material | Specification | Code |
|---|---|---|---|---|
| Proximal Femoral Nail Antirotation Intramedullary Nail | SGM-IIK | Titanium Alloy | 12.0×170×130° | 15642170 |
| Proximal Femoral Nail Antirotation Intramedullary Nail | SGM-IIK | Titanium Alloy | 9.0×170×130° | 15649170 |
| Proximal Femoral Nail Antirotation Intramedullary Nail | SGM-IIK | Titanium Alloy | 9.0×200×130° | 15649200 |
| Proximal Femoral Nail Antirotation Intramedullary Nail | SGM-IIK | Titanium Alloy | 9.0×240×130° | 15649240 |
| Proximal Femoral Nail Antirotation End Cap | SGM-IIK | Titanium Alloy | 10×15 | 15601115 |
| Proximal Femoral Nail Antirotation End Cap | SGM-IIK | Titanium Alloy | 10×20 | 15601120 |
| Proximal Femoral Nail Antirotation Blade | SGM-IIK | Titanium Alloy | 10.5×70 | 15600570 |
| Proximal Femoral Nail Antirotation Blade | SGM-IIK | Titanium Alloy | 10.5×80 | 15600580 |
| PFNA φ4.9 Locking Screw | SGM-IIK | Titanium Alloy | 4.9×30--72 | 15604930 |
| Femoral Nail Locking Screw I | SGG-IIIK | Titanium Alloy | 6.5×75 | 15246575 |
| Femoral Nail Intramedullary Nail | SGG-IIIK | Titanium Alloy | 9.0-13.0 | 15249340 |
| Humeral Nail Intramedullary Nail | SHG-IK | Titanium Alloy | 8 | 15728160 |
The length is perfectly consistent with the anatomy of the femoral medullary cavity, ensuring optimal fit and stability.
Designed to further improve fixation strength in cases of osteoporosis. The blunt end design of the locking screw reduces the risk of excessive penetration.
Available in short (160mm) and long (180-315mm) versions with multiple diameters. All nails feature left and right types in titanium alloy, suitable for diverse clinical applications.
Proximal Fixation
Multi-plane locking options for optimal stability. Screw-in-screw design for osteoporosis strength. Blunt head and countersinking design to reduce tissue irritation.
Distal Fixation
Two or three locking holes located in safe areas to avoid vital vessels and nerves. Facilitates manual operation and prevents rotation/displacement.
Elastic Nail
Nail diameter optimized for 30-40% of the medullary cavity. Specific sizes available for ages 6-14 years.
Compression System
Special compression hole design increases stability for transverse fractures with a self-sustaining mechanism.