External Ankle Fixation Veterinary Large Fragment Set Implant Ortopedic Bone Lengthening Fixator Individuals Pin Hoffman Clamp

Product Description

External Ankle Fixation Veterinary Large Fragment Set Implant Orthoped Bone Lengthening Fixator Individuals Pin Hoffman Clamp
External Ankle Fixation
📦 Product Description
Product Detail 1
Product Detail 2
Product Detail 3
Product Detail 4
⚠️ Technical Notes & Maintenance
Sterilize temperature ≤ 135 °C (Improved type ≤ 155 °C). Exceeding 135 °C may damage the motor.
Normal bone drills hold bits < 6mm. Acetabulum reaming drills (torque-focused) run at ~300 rpm, while cannulated drills (with nails/K-wires) run at ~600 rpm.
Batteries must be removed from the power tool after surgery to prevent automatic discharge and shorten battery life.
The battery is not autoclavable and cannot be sterilized.
Cranial burs should be washed immediately after surgery to avoid blood adhesion, then dried thoroughly.
Ensure the battery compartment in the handpiece remains free of water after sterilization.
Cranial bur blades are medical stainless steel; they are flexible to avoid breakage but can wear down. We suggest using each blade for only one surgery.
⭐ Related Products
You May Like
📜 Industry Certifications

CE / ISO13485 / GMP / FSC

Certification
🌍 Global Exhibitions
Exhibition 1
Exhibition 2
🚚 Packaging & Shipping
Packing: Optional Aluminum case for each set, then packed into a high-quality carton or customized upon request.
Shipping: Door-to-door courier via DHL, TNT, UPS, FEDEX, or shipment via air/sea.
Shipping and Packaging
Frequently Asked Questions
Q1: What is the recommended sterilization temperature for the equipment? A: The standard sterilization temperature should be ≤ 135 °C. For improved types, it can reach up to 155 °C. Exceeding these limits may damage the internal motor.
Q2: Can the power tool batteries be autoclaved? A: No, the batteries are not autoclavable and cannot be sterilized. They should be removed from the handpiece after surgery.
Q3: What are the different RPM settings for the medical drills? A: Acetabulum reaming drills operate at approximately 300 rpm for high torque, while cannulated drills used with nails or K-wires operate at around 600 rpm.
Q4: How should the cranial bur be maintained after use? A: The cranial bur must be washed immediately after surgery to prevent blood from sticking, and then dried. It is suggested that each blade be used for only one surgery.
Q5: What shipping methods are available for international orders? A: We offer door-to-door courier services including DHL, TNT, UPS, and FEDEX, as well as standard air and sea freight options.
Q6: What certifications do your veterinary implants and tools hold? A: Our products are manufactured according to national GMP standards and hold CE, ISO13485, and FSC certifications.